+886-2-8772-8910
Sensor head |
H12684-365 |
H12684-385 |
H12684-395 |
H12684-405 |
Unit |
|
Controller |
C12144 |
|||||
Sensitive wavelength range |
320 to 400 |
300 to 470 |
nm |
|||
Wavelength of maximum sensitivity |
370 |
395 |
nm |
|||
Calibrated wavelength |
365 |
385 |
395 |
405 |
nm |
|
Effective area |
1 mm |
mm |
||||
Measurement |
Irradiance |
0.1 mW/cm2 to 100 W/cm2 |
— |
|||
Integrated power |
0.1 mJ/cm2 to 9999 J/cm2 |
— |
||||
Measurement |
Irradiance |
Irradiance measurement and display mode (mW/cm2) |
mW/cm2 |
|||
Integrated power |
Integrated power measurement and display mode (mJ/cm2) |
mJ/cm2 |
||||
Irradiance peak hold |
Peak irradiance display mode during measurement (mW/cm2) |
mW/cm2 |
||||
External interface |
RS-232C, USB 2.0 |
— |
||||
Power requirement |
Two AAA batteries / Dedicated AC adapter / USB |
— |
||||
Weight |
Approx. 195 |
g |
||||
Operating ambient temperature / humidity |
0 °C to +40 °C / Below 80 % |
— |
||||
Storage ambient temperature / humidity |
-20 °C to +60 °C / Below 80 % |
— |
Parameter |
Controller: C10427, Sensor Head: H10428 |
Unit |
||
---|---|---|---|---|
Spectral Response Range |
310 to 380 |
nm |
||
Effective Sensor Diameter |
10 |
mm |
||
Measurement Range |
0.001 to 100 (measuring range switching : 4-stage) |
mW/cm2 |
||
Measurement Mode |
Continuous |
Displays every 0.5 seconds |
— |
|
Integration |
Displays value integrated for a certain time |
— |
||
Peak Hold |
Displays peak value during measurement |
— |
||
Temperature |
Measures sensor temperature (sensor is mounted in head) |
— |
||
Analog Output |
0 to +2 ① |
V |
||
External Interface |
USB2.0 / RS-232C |
— |
||
Power Requirement |
AC adapter or two AAA battery ② |
— |
||
Weight |
Controller + sensor head |
Approx. 170 (including two AAA battery) |
g |
|
Controller + connection cable + sensor head |
Approx. 300 (including two AAA battery) |
g |
||
Operating ambient temperature / humidity |
0 °C to +40 °C / 80 % or less |
— |
||
Storage ambient temperature / humidity |
-20 °C to +50 °C / 80 % or less |
— |
CHARACTERISTICS
OVERVIEW
Display |
Liquid crystal digital display [irradiance (mW/cm2) / integrated optical power (mJ/cm2): Max.effective 4 digits] |
---|---|
Function |
Real time / Integration / Peak hold / Temperature |
Integration Time Setting |
1 s to 5 min (1 s step) |
Analog Output |
0 V to +2 V |
External Interface |
RS-232C |
Power Requirement |
Rechargeable battery (built-in) / AC adapter (AC100 V to 240 V) (supplied) |
Operating Ambient Temperature / Humidity |
0 °C to +40 °C / Below 80 % (no condensation) |
Storage Temperature / Humidity |
-20 °C to +50 °C / Below 80 % (no condensation) |
Weight |
Approx. 285 g |
Type |
H9535-126 |
H9535-146 |
H9535-172 |
H9535-222 |
H9535-185 |
H9535-254 |
Unit |
---|---|---|---|---|---|---|---|
Calibrated Wavelength |
126 |
146 |
172 |
222 |
185 |
254 |
nm |
Applicable light Source |
Excimer lamp |
Low-pressure mercury lamp |
— |
||||
Sensitive Area |
6 |
mm |
|||||
Optical Power Measurement Range |
Irradiance [0.001 mW/cm2 to 200 mW/cm2] |
— |
|||||
Operating Ambient Temperature / Humidity |
0 °C to +60 °C / Below 80 % (no condensation) |
— |
|||||
Storage Temperature / Humidity |
-20 °C to +60 °C / Below 80 % (no condensation) |
— |
|||||
Weight |
Sensor Head: Approx. 60 g / Cable: Approx. 110 g |
— |
Parameter |
Description / Value |
|
---|---|---|
Measurement |
Continuous |
This mode makes continuous measurements at a sampling rate of 1 second. |
Integration |
This mode displays a result integrated over a certain period of time |
|
One Shot (C9536-01 only) |
This mode makes one measurement each time START switch is pressed. |
|
Peak Hold (C9536-02 only) |
This mode holds the peak values in continuous measurement. |
|
External Interface |
RS-232C |
|
Power Requirement |
Internal battery or AC adapter |
|
Dimensions (W × H × D) |
75 mm × 110 mm × 20 mm |
|
Operating Ambient Temperature / Humidity |
0 °C to +40 °C / Below 80 % |
|
Storage Temperature / Humidity |
-20 °C to +50 °C / Below 80 % |
|
Weight |
Approx. 285 g |
Parameter |
Description / Value |
||
---|---|---|---|
Controller and Sensor Head Combination |
C9536-01 |
C9536-02 |
|
Type |
H9958 |
H9958-01 |
H9958-02 |
Spectral Response |
310 nm to 380 nm |
300 nm to 410 nm |
|
Effective Area |
10 mm |
1 mm |
|
Measurement Range |
1 µW/cm2 to 100 mW/cm2 |
100 µW/cm2 to 10 W/cm2 |
|
Dimensions (W × H × D) |
55 mm × 75 mm × 18 mm |
||
Operating Ambient Temperature / Humidity |
0 °C to +45 °C / Below 80 % |
0 °C to +60 °C / Below 80 % |
|
Storage Temperature / Humidity |
-20 °C to +50 °C / Below 80 % |
-20 °C to +60 °C / Below 80 % |
|
Weight |
Approx. 195 g |