The C13247 is a radiation line sensor designed for an efficient, non-invasive detection of pipe corrosion in industrial plants such as oil, gas and petrochemical refineries. The C13247 ensures high accuracy that never seen up till now and reliable inspections of pipe corrosion.
In conventional visual and ultrasonic inspections, the heat insulator materials must be removed from around the pipes. This also requires the time and the cost of installing scaffolds to remove and rewrap the heat insulator materials. Other techniques that utilize conventional radiation inspection or neutron moisture measurement inspection have the problem of being easily affected by scattered radiation which makes accurate measurement difficult.
Parameter |
Description / Value |
|
---|---|---|
Detection method |
Direct radiation detection by semiconductor in photon counting mode |
|
Number of detector pixels |
64 |
|
Detector pixel pitch |
3.3 mm |
|
Energy measurement range |
50 keV to 500 keV |
|
Number of energy thresholds |
3 (Settable at any point within energy measurement range) |
|
Maximum count rate per channel |
0.5 × 106 s-1 |
|
Integration time per line |
50 ms to 4095 ms |
|
Counter |
16 bit |
|
Output |
Count (16 bit) |
|
Data output format |
CSV, Excel® |
|
External start trigger |
TTL |
|
Support OS |
Windows® 10 (64-bit version) |
|
Input voltage |
15 V DC (Supplied AC adapter: 100 to 240 V, 50 Hz / 60 Hz) |
|
Operating temperature range |
0 °C to +40 °C |
|
Operating humidity range |
30 % to 80 % (no condensation) |
|
Storage humidity range |
30 % to 80 % (no condensation) |
|
Dimensions |
Sensor unit |
250 mm × 155 mm × 30 mm / 4.5 kg |
Power supply trigger box |
220 mm × 120 mm × 80 mm / 2.5 kg |
|
Switch box |