產品介紹 Products Information

聯絡資訊 Contact
  • 半導體IC產品
  • 聯絡人: 劉小姐
  • 電話: +886-2-8772-8910 分機 619
聯絡資訊 Contact
  • 電子零件產品
  • 聯絡人: 林小姐
  • 電話: +886-2-8772-8910 分機618
聯絡資訊 Contact
  • 真空相關產品
  • 聯絡人: 王經理
  • 電話: +886-2-8772-8910 分機161
聯絡資訊 Contact
  • PCB機器
  • 聯絡人: 王小姐
  • 電話: +886-2-8772-8910 分機631
聯絡資訊 Contact
  • 化學相關產品
  • 聯絡人: 陳小姐
  • 電話: +886-2-8772-8910 分機633
聯絡資訊 Contact
  • 不確定品牌/型號
  • 聯絡人: 陳小姐
  • 電話: +886-2-8772-8910 分機633

MPPC module: C13368/ C13369 series (MCA type)

E-mail contact

+886-2-8772-8910

Features
Built-in MPPC array (1 × 16 ch or 4 × 4 ch)
High sensitivity in the short wavelength range   
Low dark count
Low afterpulses   
Digital output
 
Applications
Evaluation of MPPC arrays
Low-light-level measurement
Non-destructive inspection
Fluorescence measurement
Analytical instruments
 
 
Structure
Parameter
Symbol
C13368-3050ED-16
C13369-1025GD-04
C13369-3050ED-04
Unit
Number of channels
-
16 (1 × 16)
16 (4 × 4)
-
Effective photosensitive area/ch
-
3 × 3
1 × 1
3 × 3
mm
Pixel pitch
-
50
25
50
μm
Number of pixels/ch
-
3584
1584
3584
-
 
Absolute maximum ratings
Parameter
Symbol
Condition
Value
Unit
Operating temperature
Topr
No dew condensation*
0 to +60
°C
Storage temperature
Tstg
No dew condensation*
-20 to +80
°C
* When there is a temperature difference between a product and the surrounding area in high humidity environment, dew condensation may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability.
Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the product within the absolute maximum ratings.
 
 
Electrical and optical characteristics (Ta=25 °C, λ=λp, unless otherwise noted)
Parameter
Symbol
Condition
C13368-3050ED-16
C13369-3050ED-04
C13369-1025GD-04
Unit
Min.
Typ.
Max.
Min.
Typ.
Max.
Spectral response range
λ
 
320 to 900
nm
Peak sensitivity wavelength
λp
 
450
nm
Output stability depending on temperature
-
Ta=25 ± 10 °C
-
-
±10
-
-
±10
%
Photon detection efficiency
PDE
Threshold: 0.5 p.e.
-
40
-
-
25
-
%
Dark count/ch
-
Threshold: 0.5 p.e.
-
500
1500
-
90
270
kcps/ch
Threshold level
-
 
11 adjustable levels: 0.5 to 10.5
p.e.
Maximum count rate
-
 
-
7
-
-
10
-
Mcps
interface
-
 
USB 3.0
-
 
 
Block Diagram
 
Connection Example
Using the supplied USB cable, connect the MPPC module to a PC. Setup is done from a PC. Measured data can be displayed and saved on the PC.
 
 
Measurement example
 
 
Software
The included sample software can be used to easily perform basic operations of the MPPC module. The sample software provides functions for acquiring and saving data, drawing graphs, etc.
Systems compatible with the sample software.
The sample software has been confirmed to work with the follow- ing systems. Operation on other systems is not guaranteed.
Microsoft Windows 7 Professional
Microsoft Windows 7 Professional SP1 (32-bit, 64-bit)
 
PC with high-performance CPU and memory is recommended. This is especially true when running multiple MPPC modules simultaneously.
  Measurement Example
 
 
 
 
Dimensional outline (unit: mm)
C13368-3050EM-16
C13369-1025GM-04
C13369-3050EM-04

 

MPPC array module lineup

Type no.

Output format

Photosensitive area/ch
(mm)

Pixel pitch
(μm)

Number of channels

C13369-1025GA-04

Analog

1 × 1

25

4 × 4

C13369-3050EA-04

3 × 3

50

4 × 4

C13368-3050EA-16

3 × 3

50

1 × 16

C13369-1025GD-04

 

1 × 1

25

4 × 4

C13369-3050ED-04

Digital

3 × 3

50

4 × 4

C13368-3050ED-16

 

3 × 3

50

1 × 16

C13369-1025GM-04

MCA
(multichannel analyzer)

1 × 1

25

4 × 4

C13369-3050EM-04

3 × 3

50

4 × 4

C13368-3050EM-16

3 × 3

50

1 × 16

 

檔案下載