Spectroscopic modules

E-mail contact

+886-2-8772-8910

Features
●Compact, thin case
●MEMS-FPI spectrum sensor and light source are installed. 
●Spectral response range
C15712: 1350 to 1650 nm
C15713: 1550 to 1850 nm
C15714: 1750 to 2150 nm
●External power supply not necessary: USB 2.0 bus powered
●Transmission wavelength shift due to the ambient temperature change is corrected.
●High-speed measurement
 
Applications
●Moisture detection 
●Food inspection
●Farm product inspection 
●Plastic screening
●Fabric identification, etc.
 
Spectral measurement of textiles / MEMS-FPI spectrum sensor

Spectral measurement of plastics / MEMS-FPI spectrum sensor

 
 
Structure

Parameter

C15712

C15713

C15714

Unit

Sensor

MEMS-FPI spectrum sensor

-

C14272

C13272-03

C14273

Light source

Tungsten lamp

-

Interface

USB 2.0 micro-B

-

Dimensions

74 × 32 × 16

mm

Weight

82

g

 
 
Absolute maximum ratings

Parameter

Symbol

Value

Unit

Operating temperature*1

Topr

-5 to +50

°C

Storage temperature*1

Tstg

-20 to +70

°C

*1: No dew condensation
When there is a temperature difference between a product and the surrounding area in high humidity environments, dew condensation may occur on the product surface. Dew condensation on the product may cause deterioration in characteristics and reliability.
Note: Exceeding the absolute maximum ratings even momentarily may cause a drop in product quality. Always be sure to use the product within the absolute maximum ratings.
 
Optical characteristics (Ta=25 °C unless otherwise noted)

Parameter

Symbol

C15712

C15713

C15714

Unit

Min.

Typ.

Max.

Min.

Typ.

Max.

Min.

Typ.

Max.

Spectral response range*2

λ

1350

-

1650

1550

-

1850

1750

-

2150

nm

Spectral resolution (FWHM)*3

-

-

-

18

-

-

20

-

-

22

nm

Wavelength reproducibility*4

λr

-

±2

-

-

±2

-

-

±2

-

nm

Wavelength temperature dependence*5

λTd

-0.1

-

0.1

-0.1

-

0.1

-0.1

-

0.1

nm/°C

*2: Minimum step 0.1 nm, maximum 901 wavelength points can be set.
*3: When the light [line spectrum resolution (FWHM)=3 nm max.] is input from the optical fiber (core diameter=600 μm, NA=0.22) connected by the fiber adapter A15719.
*4: When the incident light condition and usage environment are constant
*5: Topr=-5 to +50 °C, C15712: λ=1500 nm, C15713: λ=1700 nm, C15714: λ=1950 nm
 
Electrical characteristics (Ta=25 °C unless otherwise noted)

Parameter

Specification

Unit

A/D conversion

16

bit

 

Low

1.05 × 106

Ω

Gain*6

Middle

1.05 × 107

Ω

 

High

2.23 × 107

Ω

USB bus power current consumption

Typ.

350

mA

Max.

450

*6: Design value
 
Spectral resolution vs. peak transmission wavelength (typical example)
 
Spectral response (typical example)
C15712
C15713
C15714
 
Evaluation software (accessory)
By installing the evaluation software (FPIModuleEvaluation.exe) into a PC, you can perform the following basic operations.
⸱ Acquire, save measurement data
⸱ Set measurement conditions
⸱ Set built-in lamp
⸱ Acquire module information
(type number, serial number, spectral response range, etc.)
⸱ Display graphs
⸱ Calculation functions
Comparison with the reference data (reflectance, absorbance, etc.)
Note: Up to eight spectroscopic modules can be connected to a single PC and used.
Compatible OS: Microsoft® Windows® 10 (32-bit, 64-bit)
A DLL for controlling the hardware is available.
The DLL and sample software is created in the following development environment, so users can develop original measurement programs.
DLL: Microsoft Visual Studio® 2017 Visual C++®
Sample software: Microsoft Visual Studio 2017 Visual C#®
Note: Microsoft, Windows, Visual Studio, Visual C++, and Visual C# are registered trademarks of Microsoft Corporation in the United States and/or other countries.
 
Connection examples
Reflected light measurement
Place cloth, plastic, etc. on the window material of the spectroscopic module connected to a PC via USB. The light from the light source built into the spectroscopic module strikes the object, and the spectroscopic module measures the reflected light.
 
Transmitted light measurement
When measuring transmitted light, a light source must be prepared (the light source built into the spectroscopic module cannot be used).
 
 
Measurement example (cloth)
 